T-Square Saliva Oral Mouth Swab Drug Test
The T-Square saliva oral drug test is an affordable solution for employment & insurance drug testing. Easy to use drug test with results in minutes.
Features & Benefits
- Observed Collection without privacy issues
- No Need for Restroom
- Collect & Test in One Step
- Fast & Easy to Read Result
- EMPLOYMENT & INSURANCE USE ONLY, NOT FOR CLINICAL USE
- Shelf life for T=Square is up to 24 months when stored at 40-86ºF
- Drug test results in minutes
- Saliva saturation indicator ensures sufficient specimen volume is collected
- Eliminates need for gender-specific observation
- Limits adulteration and tampering
- Slim, lightweight, convenient to store
- No special training required
- Clean, hygienic
- Economical
- No more Urine Collection
- Totally non-invasive
T-Square Panel Configurations:
Employment & Insurance Testing
5 Panel T-Square
QODOA-156NTEUO-I
AMP, COC, MET, OPI, PCP
NO THC (Marijuana)
QODOA-256EUO-I
AMP, COC, MET, OPI, THC
6 Panel T-Square
QODOA-166EUO-I
AMP, COC, MET, OPI, PCP, THC
QODOA-666EUO-I
AMP, COC, MET ,OPI, OXY,THC
QODOA-366NTEUO-I
AMP, COC, MET, OPI, OXY, PCP
NO THC (Marijuana)
7 Panel T-Square
QODOA-376EUO-I
AMP, COC, MET, OPI, OXY, PCP, THC
9 Panel T-Square
QODOA-496NTEUO-I
AMP, BAR, COC, MDMA, MET, MTD, OPI, OXY, PCP
NO THC (Marijuana)
10 Panel T-Square
QODOA-10106EUO-I
AMP, BAR, COC, MDMA, MET, MTD, OPI, OXY, PCP, THC
T-Square Oral Drug Test
Forensic Use Only – NOT For Employment Testing
6 Panel T-Square
QODOA-266-I 6-Panel with indicator
AMP, BZO, COC, MET, OPI, THC
8 Panel T-Square
QODOA-186-I
AMP. BUP, BZO, COC, MET, OPI, OXY, THC
7 Panel T-Square
QODOA-376-A
AMP, COC, MET,OPI, PCP, THC + ALC
10 Panel T-Square
QODOA-2106 10-Panel
AMP, BUP, BZO, COC, MET, MTD, OPI, OXY, PCP, THC
QODOA-2106-I 10-Panel with indicator
AMP, BUP, BZO, COC, MET, MTD, OPI, OXY, PCP, THC
QODOA-5106 10-Panel
AMP, BAR, BUP, BZO, COC, MET, OPI, OXY, PCP, THC
11 Panel T-Square
QODOA-1116-A
AMP. BAR, BUP. BZO. COC, MET, MTD, OPI, OXY, PCP + ALC
QODOA-2116-A
AMP, BAR, BUP, BZO, COC, MET, OPI, OXY, PCP, THC + ALC
QODOA-5116-I
AMP, BAR, BUP. BZO, COC, MET, MDMA, MTD, OXY, OPI, THC
QODOA-4116-A 11-Panel
AMP, BAR, BZO, COC, MET, MTD, OPI, OXY, PCP, THC+ALC
12 Panel T-Square
QODOA-3126-A 12-Panel
AMP, BAR, BUP, BZO, COC, MET, MTD,OPI, OXY, PCP,THC+ALC
QODOA-6126 12-Panel
AMP, BAR, BUP, BZO, COC, MDMA, MET, MTD, OPI, OXY, PCP, THC
QODOA-6126-I
AMP. BAR, BUP, BZO, COC, MDMA, MET, MTD, OPI, OXY, PCP, THC
What does this mean? Forensic Use Only devices are intended for use only in drug testing for law enforcement purposes. Appropriate users of such devices include, for example, court systems, police departments, probation/parole offices, juvenile detention centers, prisons, jails, correction centers and other similar law enforcement entities, or laboratories or other establishments performing forensic testing for these entities. Forensic Use Only devices are not designed, tested, developed, or labeled for use in other settings, such as clinical diagnostic or workplace settings.
T-Square Drug Test Procedure
Allow the kit and specimen to come to room temperature (65°F-86°F/18°C-30°C) prior to testing. AVOID PLACING ANYTHING IN THE MOUTH 10 MINUTES PRIOR TO TESTING.
1. Remove the test cube and the sponge collector from the foil pouch by tearing at the notch. Place the test cube upright on a level surface.
2. Put the sponge end of the collector in your mouth to collect oral fluid for about 7 minutes or until the sponge is fully saturated by oral fluid. Do not chew, bite or suck the sponge. If the amount of oral fluid does not make the sponge fully saturated within 7 minutes, repeat the collection using one additional sponge collector provided, beginning with Step 1.
Note: In case of the dry mouth, do not swallow oral fluid during collection.
3. Open the test cube and place the fully saturated sponge collector inside the test cube. Press the sponge collector down firmly until it reaches the bottom of the test cube, then close the cube lid tightly while compressing the collector. Keep test cube upright on flat surface and follow Step 4.
Note: Make sure the sponge collector is inserted vertically and the handle of collector is
put into the clamp.
4. Interpreting Drug Test Results:
Read results at 5 minutes. Do not read after 5 minutes.
INTERPRETATION OF RESULTS
Negative (-)
A colored band is visible in the Control Region (C) and the appropriate Test Region (T). It indicates that the concentration of the corresponding drug of that specific test zone is zero or below the detection limit of the test.
Preliminary Positive (+)
A colored band is visible in the Control Region (C). No colored band appears in the appropriate Test Region (T). It indicates a positive result for the corresponding drug of that specific Test Region (T).
Invalid
If a colored band is not visible in the Control Region (C), the test is invalid. Another test should be run to re-evaluate the specimen. If test still fails, please contact the distributor with the lot number. Note: There is no meaning attributed to line color intensity or width